User's Guide

UL865 Hardware User Guide
1VV0301050 Rev 2 – 2013-10-09
An AT command is available to use the DAC function.
The command is: AT#DAC= [<enable> [, <value>]]
<value> - scale factor of the integrated output voltage (0..1023 - 10 bit precision)
it must be present if <enable>=1
Refer to SW User Guide or AT Commands Reference Guide for the full description of this
function.
NOTE:
The DAC frequency is selected internally. D/A converter must not be used during
POWERSAVING.