User's Manual

UL865-N3G Hardware User Guide
1VV0301177 Rev 2– 2015-04-20
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 57 of 70
Mod. 0805 2011-07 Rev.2
14.3. VAUX Power Output
A regulated power supply output is provided in order to supply small devices from the
module. The signal is present on Pad 43 and it is in common with the PWRMON (module
powered ON indication) function.
This output is always active when the module is powered ON.
The operating range characteristics of the supply are:
Level Min Typical Max
Output voltage 1.78V 1.80V 1.82V
Output current - - 60mA
Output bypass capacitor
(inside the module)
1uF