User's Manual

UE910 V2 Hardware User Guide
1VV0301065 Rev.1 2013-12-12
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved. Page 50 of 67
10.5. RTC Bypass Output
The VRTC pin brings out the Real Time Clock supply, which is separate from the rest of the digital
part, allowing having only RTC going on when all the other parts of the device are off.
To this power output a backup capacitor can be added in order to increase the RTC autonomy during
power off of the battery. NO Devices must be powered from this pin.
In order to keep the RTC active when VBATT is not supplied it is possible to back up the RTC
section connecting a backup circuit to the related VRTC signal (pad C14 on module’s Pinout).
For additional details on the Backup solutions please refer to the related application note (xE910
RTC Backup Application Note)
10.6. VAUX/PWRMON Power Output
A regulated power supply output is provided in order to supply small devices from the module. This
output is active when the module is ON and goes OFF when the module is shut down. The operating
range characteristics of the supply are:
Operating Range VAUX/PWRMON power supply
Parameter
Min
Typical
Max
Output voltage
1.77V
1.8V
1.83V
Output current
200mA
Output bypass capacitor
(Inside the module)
2.2μF