- 1. Press and hold the (+) button (“J” in Figure 3.1) for 2 seconds. The red LED (“N” in Figure 3.1) blinks slowly.
- To delete an enrolled device, proceed as follows.
- 1. Press and hold the (-) button (“J” in Figure 3.1) for 2 seconds. The red LED (“N” in Figure 3.1) blinks quickly and a happy beep is heard and then the LED turns off.
- 3.8 Panel Reset
- 3.9 Factory Default Restore
- 4. PROGRAMMING
- 4.1 General Guidance
- 4.2 Entering the "Installer Mode" and Selecting a Menu Option
- 4.3 Setting Installer Codes
- 4.4 Zones / Devices
- 4.4.1 General Guidance & Zones/Devices Menu Options
- 4.4.2 Adding New Wireless Devices
- 4.4.3 Deleting a Device
- 4.4.4 Modifying or Reviewing a Device
- 4.4.5 Replacing a Device
- 4.4.6 Configuring Soak Test Mode
- 4.4.7 Defining Configuration Defaults for "Device Settings"
- 4.4.8 Updating Devices after Exiting Installer Mode
- 4.5 Control Panel
- 4.5.1 General Guidance – "Control Panel" Flow-Chart & Menu Options
- 4.5.2 Configuring Arming/Disarming and Exit/Entry Procedures
- 4.5.3 Configuring Zones Functionality
- 4.5.4 Configuring Alarms & Troubles
- 4.5.5 Configuring Sirens Functionality
- 4.5.6 Configuring Audible & Visual User Interface
- 4.5.7 Configuring Jamming and Supervision (Missing device)
- 4.5.8 Configuring Miscellaneous Features
- 4.6 Communication
- 4.6.1 General Guidance – "Communication" Flow-Chart & Menu Options
- 4.6.2 Configuring GSM-GPRS (IP) - SMS Cellular Connection
- 4.6.3 Configuring Events Reporting to Monitoring Stations
- 4.6.4 Configuring Events Reporting to Private Users
- 4.6.5 Configuring Motion Cameras for Visual Alarm Verification
- 4.6.6 Configuring Upload / Download Remote Programming Access Permission
- 4.6.7 Broadband2F
- 4.7 Custom Names
- 4.8 Diagnostics
- 4.9 User Settings
- 4.10 Factory Default
- 4.11 Serial Number
- 4.12 Partitioning
- 4.13 Operation Mode
- 5. PERIODIC TEST
- 6. MAINTENANCE
- 7. READING THE EVENT LOG
- APPENDIX A. PowerMaster 360 Configurator
- APPENDIX B. VISONIConfig Mobile Installer App. For PowerMaster 360
- APPENDIX C. User Mobile Application with PowerMaster 360
- APPENDIX D. Specifications
- APPENDIX E. Working with Partitions
- APPENDIX F. Detector Deployment & Transmitter Assignments
- APPENDIX G. Event Codes
- APPENDIX H. Sabbath Mode
- APPENDIX I. Glossary
- APPENDIX J. Compliance with Standards
- PowerMaster 360 Quick User Guide
PowerMaster 360 Quick User Guide
PowerMaster 360 Quick User Guide
Arming and Disarming the System
Step
Operation
User Actions
Notes
Optional
1 Press the Partition Selection button and then
select a PARTITION
(if Partition is enabled) –
used to divide the alarm system into three
independently controllable areas
followed by any
combination of ,
, or
A “protest” beep will be
heard when selecting a
partition to which no
sensors / peripherals
were enrolled.
2
Arm AWAY - used to arm the system when the
protected site is vacated entirely.
+ [ ] or enter code
ARM indicator
lights steadily during
the armed state.
ARM indicator
extinguishes during the
disarmed state.
Disarming the system
also stops the siren
alarm, irrespective of
whether the alarm was
initiated during the
armed or the disarmed
state.
Arm HOME – used to arm the system when
people are present within the protected site.
+
[ ]
or enter code
Disarm (OFF) – used to restore the control panel
to the normal standby state
+ [ ] or enter code
Optional
Quick arm AWAY (If Quick Arm is enabled) –
used to arm in the AWAY state without a user
code
Quick arm HOME (If Quick Arm is enabled) –
used to arm in the HOME state without a user
code
Forced arming AWAY (system not ready) – used
to arm the alarm system in the AWAY state when
any of the system zones is disturbed
+ [ ] or enter code
to silence the “protest”
buzzer
Forced arming HOME (system not ready) – used
to arm the alarm system in the HOME state
when
any of the system zones is disturbed
+
[ ]
or enter code
to silence the “protest”
buzzer
Optional
3 INSTANT – used to arm in the Instant mode,
without an entry delay.
(After arming HOME/AWAY)
LATCHKEY – used for keyfob transmitters 5
through 8
Note: The factory default master user code is 1111. The code is not required if quick arming has been permitted by the
installer. Change the factory default code to a secret code without delay (see section Chapter 4, section B.4 of the
PowerMaster 360 User’s Guide).
Initiating Alarms
Alarms
Actions
Notes
Emergency alarm
(≈ 2 sec.)
To stop the alarm, press and then key in
your valid user code.
Fire alarm
(≈ 2 sec.)
Panic alarm
+ (≈ 2 sec.)
Preparing to Arm
Before arming, make sure that READY is displayed.
HH:MM READY
This indicates that all zones are secured and you may arm the system as desired.
If at least one zone is open (disturbed) the display will read:
HH:MM NOT READY
This indicates that the system is not ready for arming and in most cases that one or more
zones are not secured. However, it can also mean that an unresolved condition exists
such as certain trouble conditions, jamming etc., depending on system configuration.