User's Manual
Table Of Contents
- 1. INTRODUCTION
- 2. CHOOSING THE INSTALLATION LOCATION
- 3. INSTALLATION
- 3.1 Connections and LED Indications
- 3.2 Inserting the Battery
- 3.3 PowerManage 360 Connections
- 3.4 GSM Connection and Configuration
- 3.5 SIM Card Insertion
- 3.6 PowerMaster 360 Prerequisites
- 3.7 Enrolling / Deleting a Z-Wave Device
- 1. Press and hold the (+) button (“J” in Figure 3.1) for 2 seconds. The red LED (“N” in Figure 3.1) blinks slowly.
- To delete an enrolled device, proceed as follows.
- 1. Press and hold the (-) button (“J” in Figure 3.1) for 2 seconds. The red LED (“N” in Figure 3.1) blinks quickly and a happy beep is heard and then the LED turns off.
- 3.8 Panel Reset
- 3.9 Factory Default Restore
- 4. PROGRAMMING
- 4.1 General Guidance
- 4.2 Entering the "Installer Mode" and Selecting a Menu Option
- 4.3 Setting Installer Codes
- 4.4 Zones / Devices
- 4.4.1 General Guidance & Zones/Devices Menu Options
- 4.4.2 Adding New Wireless Devices
- 4.4.3 Deleting a Device
- 4.4.4 Modifying or Reviewing a Device
- 4.4.5 Replacing a Device
- 4.4.6 Configuring Soak Test Mode
- 4.4.7 Defining Configuration Defaults for "Device Settings"
- 4.4.8 Updating Devices after Exiting Installer Mode
- 4.5 Control Panel
- 4.5.1 General Guidance – "Control Panel" Flow-Chart & Menu Options
- 4.5.2 Configuring Arming/Disarming and Exit/Entry Procedures
- 4.5.3 Configuring Zones Functionality
- 4.5.4 Configuring Alarms & Troubles
- 4.5.5 Configuring Sirens Functionality
- 4.5.6 Configuring Audible & Visual User Interface
- 4.5.7 Configuring Jamming and Supervision (Missing device)
- 4.5.8 Configuring Miscellaneous Features
- 4.6 Communication
- 4.6.1 General Guidance – "Communication" Flow-Chart & Menu Options
- 4.6.2 Configuring GSM-GPRS (IP) - SMS Cellular Connection
- 4.6.3 Configuring Events Reporting to Monitoring Stations
- 4.6.4 Configuring Events Reporting to Private Users
- 4.6.5 Configuring Motion Cameras for Visual Alarm Verification
- 4.6.6 Configuring Upload / Download Remote Programming Access Permission
- 4.6.7 Broadband2F
- 4.7 Custom Names
- 4.8 Diagnostics
- 4.9 User Settings
- 4.10 Factory Default
- 4.11 Serial Number
- 4.12 Partitioning
- 4.13 Operation Mode
- 5. PERIODIC TEST
- 6. MAINTENANCE
- 7. READING THE EVENT LOG
- APPENDIX A. PowerMaster 360 Configurator
- APPENDIX B. VISONIConfig Mobile Installer App. For PowerMaster 360
- APPENDIX C. User Mobile Application with PowerMaster 360
- APPENDIX D. Specifications
- APPENDIX E. Working with Partitions
- APPENDIX F. Detector Deployment & Transmitter Assignments
- APPENDIX G. Event Codes
- APPENDIX H. Sabbath Mode
- APPENDIX I. Glossary
- APPENDIX J. Compliance with Standards
- PowerMaster 360 Quick User Guide
APPENDIX H. Sabbath Mode
D-305735 PowerMaster 360 Installer's Guide 83
APPENDIX H. Sabbath Mode
H1. General Guidance
The Sabbath Mode allows you to use the alarm system without violating the Sabbath. The basic feature of this alarm
system is that the PIR sensors are not activated during Disarm mode.
The method of installation, as illustrated in the drawing below, is used in order to prevent transmission from the
magnetic contact device. The MC-302E device is used only as a transmitting device to report the status of the door to
the control panel. A wired magnetic contact is connected to the input of the MC-302E device and an open/close switch
is connected in parallel to the MC-302E input.
Note: Before the Sabbath, closing the circuit neutralizes the detector’s magnet. You can use the front door without
violating the Sabbath. On the Sabbath day itself, you can open the switch to allow the door to be protected. This
operation is permitted on the Sabbath and also when the control panel is armed.
H2. Connection
1.
Enroll an MC-302E to the PowerMaster 360 control panel (see section 4.4.2).
2.
Configure the “Input #1” setting option of the MC-302E to “Normally Closed” (refer to the MC-302E Installation
Instructions, section 2.3).
3.
Connect to the MC-302E a wired magnetic contact to be installed on the door and that is operated by
opening/closing the door (see drawing below).
4.
An open/close switch must be connected in parallel to the input of the MC-302E.
Wiring Setup
A.
MC-302E device
B.
Wired magnetic contact
C.
Fixed frame
D.
Moving part
E.
Open/close switch
E1.
Closed
E2.
Open
H3. Arming the System by Sabbath Clock
1.
Enroll an MC-302E to the PowerMaster 360 control panel (see section 4.4.2).
2.
Configure the Zone Type to “11.Arming Key” (see section 4.4.2)
3.
Configure the “Input #1” setting option of the MC-302E to “Normally Open” (refer to the MC-302E Installation
Instructions, section 2.3).
4.
From the “03:CONTROL PANEL” menu, configure the “09:ARMING KEY” setting option to “arm HOME” (see
section 4.5.2).
Note: When the alarm system is armed at night by a Sabbath clock, the open / close switch must be opened when the
door is closed.