User's Manual
Table Of Contents
- 1. INTRODUCTION
- 2. CHOOSING THE INSTALLATION LOCATION
- 3. INSTALLATION
- 3.1 Connections and LED Indications
- 3.2 Inserting the Battery
- 3.3 PowerManage 360 Connections
- 3.4 GSM Connection and Configuration
- 3.5 SIM Card Insertion
- 3.6 PowerMaster 360 Prerequisites
- 3.7 Enrolling / Deleting a Z-Wave Device
- 1. Press and hold the (+) button (“J” in Figure 3.1) for 2 seconds. The red LED (“N” in Figure 3.1) blinks slowly.
- To delete an enrolled device, proceed as follows.
- 1. Press and hold the (-) button (“J” in Figure 3.1) for 2 seconds. The red LED (“N” in Figure 3.1) blinks quickly and a happy beep is heard and then the LED turns off.
- 3.8 Panel Reset
- 3.9 Factory Default Restore
- 4. PROGRAMMING
- 4.1 General Guidance
- 4.2 Entering the "Installer Mode" and Selecting a Menu Option
- 4.3 Setting Installer Codes
- 4.4 Zones / Devices
- 4.4.1 General Guidance & Zones/Devices Menu Options
- 4.4.2 Adding New Wireless Devices
- 4.4.3 Deleting a Device
- 4.4.4 Modifying or Reviewing a Device
- 4.4.5 Replacing a Device
- 4.4.6 Configuring Soak Test Mode
- 4.4.7 Defining Configuration Defaults for "Device Settings"
- 4.4.8 Updating Devices after Exiting Installer Mode
- 4.5 Control Panel
- 4.5.1 General Guidance – "Control Panel" Flow-Chart & Menu Options
- 4.5.2 Configuring Arming/Disarming and Exit/Entry Procedures
- 4.5.3 Configuring Zones Functionality
- 4.5.4 Configuring Alarms & Troubles
- 4.5.5 Configuring Sirens Functionality
- 4.5.6 Configuring Audible & Visual User Interface
- 4.5.7 Configuring Jamming and Supervision (Missing device)
- 4.5.8 Configuring Miscellaneous Features
- 4.6 Communication
- 4.6.1 General Guidance – "Communication" Flow-Chart & Menu Options
- 4.6.2 Configuring GSM-GPRS (IP) - SMS Cellular Connection
- 4.6.3 Configuring Events Reporting to Monitoring Stations
- 4.6.4 Configuring Events Reporting to Private Users
- 4.6.5 Configuring Motion Cameras for Visual Alarm Verification
- 4.6.6 Configuring Upload / Download Remote Programming Access Permission
- 4.6.7 Broadband2F
- 4.7 Custom Names
- 4.8 Diagnostics
- 4.9 User Settings
- 4.10 Factory Default
- 4.11 Serial Number
- 4.12 Partitioning
- 4.13 Operation Mode
- 5. PERIODIC TEST
- 6. MAINTENANCE
- 7. READING THE EVENT LOG
- APPENDIX A. PowerMaster 360 Configurator
- APPENDIX B. VISONIConfig Mobile Installer App. For PowerMaster 360
- APPENDIX C. User Mobile Application with PowerMaster 360
- APPENDIX D. Specifications
- APPENDIX E. Working with Partitions
- APPENDIX F. Detector Deployment & Transmitter Assignments
- APPENDIX G. Event Codes
- APPENDIX H. Sabbath Mode
- APPENDIX I. Glossary
- APPENDIX J. Compliance with Standards
- PowerMaster 360 Quick User Guide
APPENDIX G. Event Codes
D-305735 PowerMaster 360 Installer's Guide 81
APPENDIX G. Event Codes
G1. Contact ID Event Codes
Code
Definition
Code
Definition
101
Emergency
110
Fire
351
Telco fault
114
Heat
373
Fire detector trouble
120
Panic
374
Exit error alarm (zone)
121
Duress
350
Communication trouble
122
Silent
380
Sensor trouble
123
Audible
381
Inactive event
129
Confirm panic
383
Sensor tamper
131
Perimeter
384
RF low battery
132
Interior
389
Sensor self-test failure
133
24 Hour (Safe)
391
Sensor Watch trouble
134
Entry/Exit
393
Fire detector clean me
137
Tamper/CP
401
O/C by user
139
Burglary verified
403
Auto arm
140
General alarm
406
Cancel
151
Gas alarm
408
Quick arm
152
Freezer alert
412
Successful download/access
153
Freeze alert
426
Door open event
154
Flood alarm
441
Armed home
158
High temperature
454
Fail to arm
159
Low temperature
455
Autoarm failed
180
Gas trouble
456
Partial arm
220
Guard sensor alarmed
459
Recent close event
301
AC loss
570
Bypass
302
Low system battery
602
Periodic test report
311
Battery disconnect
607
Walk test mode
313
Engineer reset
625
Time/Date change
321
Fuse
627
Program mode entry
333
Expansion modem failure
628
Program mode exit
344
RF receiver jam detect
641
Senior watch trouble
G2. SIA Event Codes
Code
Definition
Code
Definition
AR
AC Restore
LT
Phone Line Trouble
AT
AC Trouble
LX
Local Programming Ended
BA
Burglary Alarm
OP
Opening Report
BB
Burglary Bypass
OT
Fail to Arm
BC
Burglary Cancel
PA
Panic Alarm
BJ
Burglary Trouble Restore
PR
Panic Restore
BR
Burglary Restore
QA
Emergency Alarm
BT
Burglary Trouble / Jamming
RN
Engineer Reset
BV
Burglary Verified
RP
Automatic Test
BX
Burglary test
RS
Remote Program Success
BZ
Inactive event
RX
Manual Test
CF
Forced Closing
RY
Exit from Manual Test
CG
Armed home
TA
Tamper Alarm
CI
Fail to Close
TE
Communicator restored to operation
CL
Armed Away
TR
Tamper Restore
CP
Auto Arm
TS
Communicator taken out of operation
CR
Recent Close
UJ
Detector mask restore
EA
Door Open
UT
Detector mask
FA
Fire Alarm
WA
Flood alarm
FJ
Fire detector trouble
WR
Flood alarm restore
FR
Fire Restore
XR
Sensor Battery Restore