User's Manual
UE866 HARDWARE USER GUIDE 1vv0301157 Rev.7 • 2015-04-17 62 of 68
Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved
10.2 Moisture sensitivity
The UE866 is a Moisture Sensitive Device level 3, in according with standard IPC/JEDEC J-STD-020,
take care all the relatives requirements for using this kind of components.
Moreover, the customer has to take care of the following conditions:
a) Calculated shelf life in sealed bag: 12 months at <40°C and <90% relative humidity (RH).
b) Environmental condition during the production: 30°C / 60% RH according to IPC/JEDEC J-STD-
033A paragraph 5.
c) The maximum time between the opening of the sealed bag and the reflow process must be 168
hours if condition b) “IPC/JEDEC J-STD-033A paragraph 5.2” is respected
d) Baking is required if conditions b) or c) are not respected
e) Baking is required if the humidity indicator inside the bag indicates 10% RH
or more