User's Guide

UC864-E-AUTO / AWS-AUTO Hardware User Guide
1vv0300795 Rev.11 – 2010/11/18
Reproduction forbidden without Telit Communications S.p.A’s. written authorization - All Rights Reserved. Page 30 of 78
6.2.2. Thermal Design Guidelines
The thermal design for the power supply heat sink must be done with the following
specifications:
Average current consumption during HSDPA transmission @PWR level
max in UC864-E-AUTO / AWS-AUTO : 730mA
Average current consumption during class12 GPRS transmission @PWR
level max: 650mA
NOTE:
NOTE: NOTE:
NOTE:
For all the threshold voltages, inside UC864-E-AUTO / AWS-AUTO, all thresholds are
fixed in order to maximize Li-Ion battery performances and do not need to be
changed.
NOTE:
NOTE: NOTE:
NOTE:
In this application the battery charger input current must be limited to less than
400mA. This can be done by using a current limited wall adapter as the power
source.
NOTE:
NOTE: NOTE:
NOTE:
When starting the charger from Module powered off, the startup will be in CFUN4; to
activate the normal mode a command AT+CFUN=1 has to be provided.
There is also the possibility to activate the normal mode using the ON_OFF* signal.
In this case, when HW powering off the module with the same line (ON_OFF*) and
having the charger still connected, the module will go back to CFUN4.
NOTE:
NOTE:NOTE:
NOTE:
It is important to have a 100ųF Capacitor to VBAT in order to avoid instability of the
charger circuit if the battery is accidentally disconnected during the charging activity.