User's Guide
UC864-E-AUTO / AWS-AUTO Hardware User Guide
1vv0300795 Rev.11 – 2010/11/18
Reproduction forbidden without Telit Communications S.p.A’s. written authorization - All Rights Reserved. Page 16 of 78
For example:
1- Let us assume you need to drive the ON/OFF# pad with a totem pole output of a
+1.8/5 V microcontroller (uP_OUT1):
NOTE:
NOTE: NOTE:
NOTE:
To check if the UC864-E-AUTO / AWS-AUTO has powered on, the hardware line
PWRMON must be monitored. When PWRMON goes high, the module has powered
on.
NOTE:
NOTE: NOTE:
NOTE:
Do not use any pull up resistor on the ON/OFF# line, it is internally pulled up. Using
pull up resistor may bring to latch up problems on the UC864-E-AUTO / AWS-AUTO
power regulator and improper power on/off of the module. The line ON/OFF# must
be connected only in open collector configuration.
NOTE:
NOTE: NOTE:
NOTE:
In this document all the lines are inverted. Active low signals are labeled with a name
that ends with a "#" or with a bar over the name.
NOTE:
NOTE: NOTE:
NOTE:
UC864-E-AUTO / AWS-AUTO
turns fully on also by supplying power to the Charge pad
(provided there is a battery on the VBATT pads).
1s
10k
1.8 / 5V