5.2. Initialization and Activation state
Upon turning on UC864-E-AUTO / AWS-AUTO, the module is not activated yet
because the boot sequence of UC864-E-AUTO / AWS-AUTO is still going on internally.
It takes about 10 seconds to complete the initializing the module internally.
For this reason, it would be useless to try to access UC864-E-AUTO/ AWS-AUTO
during a
Initialization state
as below. To get the desirable stability, UC864-E-AUTO /
AWS-AUTO needs at least 10 seconds after the PWRMON goes High.
During the
Initialization state
, any kind of AT-command is not available. DTE must be
waiting for the
Activation state
to communicate with UC864-E-AUTO / AWS-AUTO.