User's Manual

Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved page 173 of 202
5.8.4.4 #DSTO – Data Sending Timeout control
#DSTO –Data Sending Timeout control
Execute command
Read command
AT#DSTO?
Reports the current value of the parameter <time>.
Write command
AT#DSTO=<time>
This timeout applies when the data to be sent is less that one full packet size and
whose sending would have been delayed for a undefined time until new data to be
sent is received and the full packet size is reached.
This command sets the maximum time that the module awaits before sending anyway
a packet whose size is less than the default one.
Parameter:
<time> - packet sending timeout in 100ms units
0 - no timeout, wait forever for packets to be completed before send.
1…255 hundreds of ms
Test command
AT#DSTO=?
Returns the allowed values for the parameter <time>.
Example AT#DSTO = 10 ( 1 sec. Timeout )
OK
AT#DSTO?
#DSTO: 10
OK
NOTE In order to avoid possible low performances issues, it is suggested to set the <time>
parameter to a value greater than 5
Reference
Telit specifications
SW release
Version A