User's Manual
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved page 167 of 202
Test command
AT+FPR=?
Returns all supported values of the parameters <rate>.
Example
Reference
ITU T.31 and TIA/EIA-578-A specifications
SW release
Version A
5.7.3.3 +FDD – Double escape character replacement control
+FDD – Double escape character replacement control
Execute command
Read command
Write command
AT+FDD=<mode>
This command sets the double escape character replacement behavior of the module
depending on the parameter <mode>.
Parameter
<mode>= 0
DCE decode of <DLE><SUB>: <DLE><DLE> or discard
DCE encode of <1/0><1/0>: <DLE><DLE><DLE><DLE>
Test command
AT+FDD=?
Returns all supported values of the parameters <mode>.
Example
Reference
ITU T.31 and TIA/EIA-578-A specifications
SW release
Version A