User's Manual

Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved page 156 of 202
5.6.1.20 #ACAL – Set Automatic Call
#ACAL – set automatic call
Execute command
Read command AT#ACAL?
Returns the current status in the format:
#ACAL: <mode>
Write command
AT#ACAL = <mode>
Enable the automatic call.
Parameter:
<mode> = 0 – disable
<mode> = 1 – enable
If enabled, the transition OFF/ON of DTR causes an automatic data call to the
number stored in position number 1 of the phone book.
The &D command must be set to 2.
Test command
AT#ACAL=?
Returns the supported range of values of the parameter <mode>.
Example
Reference Telit TRIZIUM AT Command Specification
SW release Future SW Version