User's Manual

Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved page 127 of 202
5.5.1.8 +CSCB – Select Cell Broadcast Message types
+CSCB –select Cell Broadcast Message types
Execute command
Read command
AT+CSCB?
Reports the current value of the parameters <mode>,<misd> and <dcss> in the
format:
+CSCB: <mode>,<mids>,<dcss>
Write command
AT+CSCB=
<mode>[,<mids>[,<dcss>]]
Selects the Cell Broadcast message types to be received by the device.
Parameter:
<mode>
0 - the message types defined by <mids> and <dcss> are accepted
1 - the message types defined by <mids> and <dcss> are rejected
<mids> : all the possible combinations of the CBM identifiers
<dcss> : all the possible combinations of CBM data coding schemes.
Test command
AT+CSCB=?
Return the possible range of values for the parameter <mode>.
Example AT+CSCB?
+CSCB: 1,"","" (all CBMs are accepted, none is rejected)
OK
AT+CSCB=0,"0,1,300-315,450","0-3"
OK
Reference GSM 07.05
SW release Version A