6.3 Activate Logging
6.3.1 Basic Configuration of Logging
The Logging functionality allows data to be stored on the APS-NR2's internal disk.
This disk has a capacity of 8GB.
The user may select SBF blocks (Septentrio Binary Format) and/or NMEA messages
(National Marine Electronics Association) to be logged.
Data logged can be downloaded in the File Explorer menu by clicking the green arrow in
the Download column.
The downloaded file will be in the browser’s download directory.
Figure 19: Logging Tab
1. Click on the tab.
2. Check the required SBF blocks and NMEA messages.
3. Select the logging interval.
4. Activate the logging by setting Logging to on.