User's Guide
ATOP3.5G Product Description
80447ST10636A rev.10 – 2015-03-03
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 43 of 66
Mod. 0808 2011-07 Rev.2
Table 29 Receiver sensitivity in GSM
Typical values measured on TELIT reference board at 3.8 V and for T
amb
= 25 °C for all channels; 3GPP requirement is 102
dBm; for T
amb
= 25 °C and all voltage conditions (3.4 V V
BAT(VBAT_PA_SNK)
4.4 V).
Symbol Parameter Conditions Min Typ Max Unit
S
RX
receiver sensitivity GSM850 band -
110.3
- dBm
GSM900 band -
111.3
- dBm
DCS1800 band -
108.6
- dBm
PCS1900 band -
108.9
- dBm
Table 30 Receiver sensitivity in UMTS
Typical values measured on TELIT reference board at 3.8 V and for T
amb
= 25 °C for all channels; 3GPP requirement is band
specific; for T
amb
= 25 °C and all voltage conditions
(3.4 V V
BAT(VBAT_PA_SNK)
4.4 V).
Symbol Parameter Conditions Min Typ Max Unit
S
RX
receiver sensitivity
band I 3GPP requirement is 106.0
-
109.5
- dBm
band II 3GPP requirement is 104.0
-
110.3
- dBm
band III (IX) 3GPP requirement is 103.3
-
<tbd>
- dBm
band IV 3GPP requirement is 106.0
-
110.1
- dBm
band V (VI) 3GPP requirement is 104.0
-
111.2
- dBm
band VIII 3GPP requirement is 103.0
-
111.0
- dBm