User's Guide

ATOP3.5G Product Description
80447ST10636A rev.10 2015-03-03
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 45 of 66
Mod. 0808 2011-07 Rev.2
15 Test and qualification information
ATOP 3.5G is a class A digital device for use in a commercial, industrial or business environment.
It is tested to conform to FCC and AT&T as well as to R&TTE articles 3.1(a) and (b), safety and
EMC respectively and relevant article 3.2 requirements using the TELIT reference board. The
manufacturer of the final product integrating ATOP 3.5G must assess its equipment against the
essential requirements of the R&TTE, FCC and AT&T directives.
ATOP 3.5G is targeted to be compliant with the following standards:
Mandatory European standards
o R&TTE Article 3.1a: Electrical safety (EN60950)
o R&TTE Article 3.1a: SAR (EN62209-1): MPE calculation as distance > 20 cm
o R&TTE Article 3.1b: EMC (EN62311:2008, EN301489-1, and EN301489-7 for
GSM, EN301489-24 for UMTS)
o R&TTE Article 3.2: Radiated RF (EN301511 for GSM, EN301908-1/-2 for UMTS,
EN300440-1/-2 for GPS, EN300291-1/-2 for NFC)
o Notified Body opinion according to Annex IV: Evaluation of compliance with
essential requirements
Mandatory US and Canadian standards
o FCC EMC: part 15B
o FCC RF: part 24 for PCS1900, part 22 for GSM850, part 15.225 for NFC
o FCC certificate from Telecom Certification body
Voluntary certification
o Global Certification Forum (GCF), including Field Tests
o PCS-1900 Type Certification Review Board (PTCRB)
o AT&T certificate
o Certification for Japanese Radio and Telecommunication law (TELEC)
Certification reports are available upon request.
SAR according to EN 62209-1 has not been checked and replaced by MPE calculation. Hence
the antenna(s) used in the final application must be installed to provide a separation distance of
at least 20 centimeters from all persons and must not be co-located or operating with any other
antenna or transmitter. Additionally, for FCC compliance, the system antenna(s) gain must not
exceed 3 dBi for mobile and fixed or mobile operating configurations.
The manufacturer of the final product using ATOP 3.5G will have to provide instructions for
antenna installation and transmitter operating conditions to satisfy to RF exposure compliance.
The manufacturer of the final product using ATOP 3.5G should take care that ATOP 3.5G is
always within the operating limits (temperature, power supply, …) described in the present
document. In particular it must be supplied by a limited power source according to EN 60950-1.
Physically, the clearance and creepage distances required by the end product must be upheld
when the module is installed. The cooling of the end product shall not negatively be influenced by
the installation of the module.
Manufacturers of devices incorporating this module are advised to clarify any regulatory
questions and to have their complete product tested and approved for R&TTE, FCC, AT&T
compliance and all relevant regulations.