User Guide
ME910G1 Preliminary HW Design Guide
1VV0301593 Rev.2 Page 83 of 95 2020-01-13
Packaging detail
Moisture sensitivity
The ME910G1 is a Moisture Sensitive Device level 3, in according with standard
IPC/JEDEC J-STD-020, take care all the relatives requirements for using this kind of
components.
Moreover, the customer has to take care of the following conditions:
a) Calculated shelf life in sealed bag: 12 months at <40°C and <90% relative humidity
(RH).
b) Environmental condition during the production: 30°C / 60% RH according to
IPC/JEDEC J-STD-033A paragraph 5.
c) The maximum time between the opening of the sealed bag and the reflow process must
be 168 hours if condition b) “IPC/JEDEC J-STD-033D paragraph 5.2” is respected
d) Baking is required if conditions b) or c) are not respected
e) Baking is required if the humidity indicator inside the bag indicates 10% RH
or more