User's Guide
ME910C1 HW User Guide
1VV0301351 Rev. 2 Page 43 of 81 2017-07-19
where 80mA is a typical current during fast shut down procedure, 300ms is the typical
time to execute the shutdown and 0.5V is the minimum voltage marging from threshold of
ME910C1 hardware reset.
TIP:
Make the same plot during system verification to check timings and
voltage levels.
5.5.2. Fast Shut Down by Software
The Fast Power Down can be triggered by AT command.