User Guide

LM960 HW Design Guide
1VV0301485 Rev. 15 Page 35 of 88 2020-08-13
Mode Average [Typ.] Mode Description
2DL CA with 2x2
MIMO / 2UL CA
900mA
CA_2A-5A, 2x2 MIMO, Full RB, 256QAM DL
/ 64QAM UL (FDD 300Mbps DL / 150Mbps
UL)
5DL CA with 2x2
MIMO / 1UL
1000mA
CA_2A-5B-66A-66A, 2x2 MIMO, Full RB,
256QAM DL / 64QAM UL (FDD 1Gbps DL /
75Mbps UL)
3DL CA with 4x4
MIMO / 1UL
1200mA
CA_2A-66C, 4x4 MIMO, Full RB, 256QAM
DL / 64QAM UL (FDD 1.2Gbps DL / 75Mbps
UL)
Operative Mode (WCDMA)
WCDMA Voice 750 mA WCDMA voice call (Tx = 23 dBm)
WCDMA HSPA
(22 dBm)
650 mA
WCDMA data call (DC-HSDPA up to 42
Mbps, Max Throughput)
* Worst/best case current values depend on network configuration - not under module
control.
** Loop-back mode in call equipment
*** 3.3 V voltage / room temperature
Information The electrical design for the power supply must ensure
a peak current output of at least 2A.
General Design Rules
The principal guidelines for the Power Supply Design embrace three different design
steps:
Electrical design
Thermal design
PCB layout
4.3.1. Electrical Design Guidelines
The electrical design of the power supply strongly depends on the power source from
which power is drained.