User's Manual

LE940B6 Hardware User Guide
1VV0301331 Rev. 1.8 - 2017-03-15
Reproduction forbidden without written authorization by Telit Communications S.p.A. - All Rights Reserved
Telit Confidential Information, provided under NDA Page
60 of 104
6.2.1.3. Battery Source Power Supply – Design Guidelines
The desired nominal output for the power supply is 3.8V, and the maximum allowed voltage
is 4.2V. Hence, a single 3.7V Li-Ion cell battery type is suitable for supplying the power to the
LE940B6 module.
NOTE:
Do not use any Ni-Cd, Ni-MH, and Pb battery types directly connected to the LE940B6 module.
Their use can lead to overvoltage on the LE940B6 and damage it. Use only Li-Ion battery types.
A bypass low ESR capacitor of adequate capacity must be provided to cut the current
absorption peaks; a 100μF tantalum capacitor is usually suitable.
Make sure that the low ESR capacitor (usually a tantalum one) is rated at least 10V.
A protection diode must be inserted close to the power input to protect the LE940B6 module
from power polarity inversion. Otherwise, the battery connector must be done in a way to
avoid polarity inversions when connecting the battery.
The battery capacity must be at least 500 mAh to withstand the current peaks of 2A. The
suggested capacity is from 500 mAh to 1000 mAh.