User's Manual
LE940B6 Hardware User Guide
1VV0301331 Rev. 1.8 - 2017-03-15
Reproduction forbidden without written authorization by Telit Communications S.p.A. - All Rights Reserved
Telit Confidential Information, provided under NDA Page
45 of 104
Figure 4: LE940B6 Initialization and Activation
NOTE:
To check whether the LE940B6 has completely powered on, monitor the SW_RDY hardware line.
When SW_RDY goes high, the module has completely powered on and is ready to accept AT
commands.
NOTE:
Do not use any pull-up resistor on the ON_OFF_N line as it is internally pulled up. Using a pull-up
resistor may cause latch-up problems on the LE940B6 power regulator and improper powering
on/off of the module. The ON_OFF_N line must be connected only in an open-collector
configuration.
NOTE:
To avoid a back-powering effect, it is recommended to avoid having any HIGH logic level signal
applied to the digital pins of the module when it is powered OFF or during an ON/OFF transition.