User's Manual

LE940B6 Hardware User Guide
1VV0301331 Rev. 1.8 - 2017-03-15
Reproduction forbidden without written authorization by Telit Communications S.p.A. - All Rights Reserved
Telit Confidential Information, provided under NDA Page
44 of 104
5. Hardware Commands
5.1. Turning on the LE940B6 Module
To turn on the LE940B6 module, the ON_OFF_N pad must be asserted low in the range of 80 - 120
milliseconds and then released.
Figure 3 illustrates a simple circuit to power on the module using an inverted buffer output.
Figure 3: Power-on Circuit
GND
R1
R2
Q1
Power ON Impulse
80ms < Hold Time < 120ms
ON_OFF_N
NOTE:
In case VBATT need to be removed and applied again. The application must take into account the
decay time of the power supply after removal of VBATT. VBATT input must be at zero volt prior
to the reapplication of VBATT."
5.2. Initialization and Activation State
After turning on the LE940B6 module, a predefined internal boot sequence performs the HW and
SW initialization of the module, which takes some time to fully complete. During this process, the
LE940B6 is not accessible.
As shown in Figure 4, the LE940B6 becomes operational at least 25 seconds after PWRMON goes
HIGH.
NOTE:
During the Initialization state, AT commands are not available. The DTE host must wait for the
Activation state prior to communicating with the LE940B6.