User's Manual
LE940B6 Hardware User Guide
1VV0301331 Rev. 1.8 - 2017-03-15
Reproduction forbidden without written authorization by Telit Communications S.p.A. - All Rights Reserved
Telit Confidential Information, provided under NDA Page
19 of 104
2.4. Environmental Requirements
2.4.1. Temperature Range
Operating
temperature range
-20 ~ +55°C.
This range is defined by 3GPP (the global standard for wireless
mobile communication). Telit guarantees its modules to comply with
all the 3GPP requirements and to have full functionality of the
module with in this range.
-40 ~ +85°C.
Telit guarantees full functionality within this range as well. However,
there may possibly be some performance deviations in this
extended range relative to 3GPP requirements, which means that
some RF parameters may deviate from the 3GPP specification in the
order of a few dB. For example: receiver sensitivity or maximum
output power may be slightly degraded.
Even so, all the functionalities, such as call connection, SMS, USB
communication, UART activation etc., will be maintained, and the
effect of such degradations will not lead to malfunction.
–40°C ~ +95°C.
eCall must be functional (until the module is broken)
Storage and non-
operating
temperature range
–40°C ~ +95°C
2.4.2. RoHS Compliance
As a part of the Telit corporate policy of environmental protection, the LE940B6 complies with the
RoHS (Restriction of Hazardous Substances) directive of the European Union (EU directive
2011/65/EU).