4.3.4. Hardware Unconditional Shutdown
To unconditionally Shutdown LE920, the pad SHDN_N must be tied low for at least 200
milliseconds and then released.
A simple circuit to do it is:
NOTE:
Do not use any pull up resistor on the SHDN_N line or any totem pole digital output. Using
pull up resistor may cause latch-up problems on the LE920 power regulator and improper
functioning of the module. The line SHDN_N must be connected only in open collector
configuration.
NOTE:
The unconditional hardware SHDN_N must always be implemented on the boards. The
software must use it as an emergency exit procedure only, and not as a normal power-off
operation.