The desired nominal output for the power supply is 3.8V and the maximum voltage
allowed is 4.2V, hence a single 3.7V Li-Ion cell battery type is suited for supplying the
power to the Telit LE910 module.
WARNING:
The three cells Ni/Cd or Ni/MH 3,6 V Nom. Battery types or 4V PB types MUST NOT BE
USED DIRECTLY since their maximum voltage can rise over the absolute maximum voltage
for the LE910 and damage it.
NOTE:
DON’T USE any Ni-Cd, Ni-MH, and Pb battery types directly connected with LE910. Their use
can lead to overvoltage on the LE910 and damage it. USE ONLY Li-Ion battery types.
A Bypass low ESR capacitor of adequate capacity must be provided in order to cut the current
absorption peaks, a 100μF tantalum capacitor is usually suited.
Make sure the low ESR capacitor (usually a tantalum one) is rated at least 10V.
A protection diode should be inserted close to the power input, in order to save the LE910 from
power polarity inversion. Otherwise the battery connector should be done in a way to avoid
polarity inversions when connecting the battery.
The battery capacity must be at least 500mAh in order to withstand the current peaks of 2A; the