Upon turning on LE910 module, The LE910 is not activated yet because the boot sequence of
LE910 is still going on internally. It takes about 10 seconds to complete the initializing the
module internally.
For this reason, it would be useless to try to access LE910 during the Initialization state as
below.
To get the desirable stability, the LE910 needs at least 15 seconds after the PWRMON goes high
to become operational by reaching the activation state.
NOTE:
Dont use any pull up resistor on the ON_OFF* line, it is internally pulled up. Using pull up
resistor may bring to latch up problems on the LE910 power regulator and improper power
on/off of the module. The line ON_OFF* must be connected only in open collector or open
drain configuration.
In this document all the lines that are inverted, hence have active low signals are labelled with a
name that ends with”#”,”*” or with a bar over the name.
During the Initialization state, any kind of AT-command is not available. DTE must be waiting
for the Activation state to communicate with LE910.
To check if the device has powered on, the hardware line PWRMON should be monitored.