16.3 Recommended foot print for the
application
TOP VIEW
In order to
easily rework the LE910 is suggested to consider on the application a 1.5 mm placement
inhibit area around the module.
It is also suggested, as common rule for an SMT component, to avoid having a mechanical
part of the application in direct contact with the module.
NOTE:
In the customer application, the region under WIRING INHIBIT (see figure above) must
be clear from signal or ground paths.