User's Guide

LE910Cx HW User Guide
Doc#: 1VV0301298
Rev. 13.0 Page 89 of 124 2019-07-15
Table 38: ADC Parameters
Min
Max
Units
Input voltage range
0.1
1.7
Volt
AD conversion
-
8
bits
Resolution
-
< 6.6
mV
9.5.2. Using the ADC Converter
An AT command is available to use the ADC function.
The command is AT#ADC=1,2. The read value is expressed in mV.
Refer to Ref 1: LE920x4/LE910Cx AT Command User Guide for the full description of this
function.
Using the Temperature Monitor Function
The Temperature Monitor supports temperature monitoring by giving periodic temperature
indications, to execute some function at extreme state. If properly set (see the
#TEMPMON command in Ref 1: LE920x4/LE910Cx AT Command User Guide), it raises a
GPIO to High Logic level when the maximum temperature is reached.