User's Guide
LE866 HARDWARE USER GUIDE 1vv0301210 Rev.0 – Preliminary • 2015-09-02 50 of 68
Reproduction forbidden without Telit Communications PLC written authorization – All Rights Reserved
6.4.4.2 Transmission Line Measurements
An HP8753E VNA (Full-2-port calibration) has been used in this measurement session.
A calibrated coaxial cable has been soldered at the pad corresponding to RF output; a SMA connector
has been soldered to the board in order to characterize the losses of the transmission line including the
connector itself. During Return Loss / impedance measurements, the transmission line has been
terminated to 50 Ω load.
Return Loss plot of line under test is shown below:
Line input impedance (in Smith Chart format, once the line has been terminated to 50 Ω load) is shown
in the following figure: