User's Manual
xE70-915 RF Module User Guide
1VV0301106 rev.3 – 2015-03-04
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 13 of 34
3.6. DC Specifications
Measured on DIP interface with T = 25°C, under 50Ω impedance connected to RF port and
default power register setting if nothing else stated.
Max limits apply over the entire operating range, T=-40°C to +85°C, Vdd=2.3V to 3.6V and
all channels.
Characteristics xE70-915 Min. Typ. Max. Unit
Power Supply (V
DD
)
+2.3 - +3.6 V
Consumption at 3.6V
Maximum output power 500mW
(+27dBm)
390 420 mA
Reception
25 30 mA
Stand-by (32.768 kHz On)
2 3 µA
I/O low level
GND - 0.2x V
DD
V
I/O high level
0.8x V
DD
- V
DD
V