14. Application guide
14.1. Debug of the HE920 in production
To test and debug the mounting of HE920, we strongly recommend foreseeing test pads on
the host PCB, in order to check the connection between the HE920 itself and the application
and to test the performance of the module connecting it with an external computer. Depending
on the customer application, these pads include, but are not limited to the following signals:
TXD
RXD
ON/OFF
RESET
GND
VBATT
TX_TRACE
RX_TRACE
PWRMON
USB_VBUS
USB_D+
USB_D-