Product Description

0x04: GPRS
0x05: FTPput
4.3.4.17 Set data mode
OPCODE:0x0011
Where field parameters is:
No parameters
In transparent mode all the data received in serial interface will be sent directly, without interpreting
them, to the UART interface of the local ZE60 and should follow the format described in document
“ZE60 Software Interface Specifications”. It is task of ZE60 FW to manage this packet and translate in
RF frame in order to send to the specific DXT.
Set data mode response
Field size Valid Range Description Default
Status 2 0x0001-0x0003 Result of the command N/A
After response, transparent mode will be available in one second.
4.3.4.18 SET Escape sequence from data mode
OPCODE:0x0012
Where field parameters is:
Sequence
Escape sequence parameter is mandatory.
Field Size Valid Range Description Default
Sequence 3 When in transparent communication this
sequence is received from host, GW
returns to Control Interface
+++
The first char in the sequence is the most left one.
After escape sequence, local SR module is turned off and control interface will be available in one
second.
Set escape sequence response
Status