Product Description
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 44 of 75
A
Scan Response,
one for each device, will be received
Parameters field of
Scan Response.
Status Address
Next table shows the valid range for the values of the parameters of the
Scan Response
.
Field size Valid Range Description Default
Status 2 0x0001-0x0004 or 0x0006 Result of the command N/A
Address 8 MAC address from
00-15-4F-00-00-00-00-00
to
00-15-4F-FF-FF-FF-FF-FE
DXT MAC address N/A
When scan is completed, status byte is 0x0004 and the other parameters are meaningless.
4.3.4.15 Set Auto DXT Data
Set parameters of Get Data from DXTs when GW is in autonomous mode. (Only for C2)
OPCODE:0x000F
Where field parameters is:
DXT list mode baro block baro mode diver block diver
No parameter is mandatory.
Field size Valid Range Description Default
DXT list 1 0x00: All the active
DXTs in the network;
0x01: All the active
DXTs from the saved list
Active DXTs or DXT list 0x00
bode baro 1 0x00: No data; 0x01:
Last data;0x02: All data;
0x03 Specific data
Get Last Data / All Data / Specific Data
or don’t get data
0x01
block baro 2 0-6000 Specific block 0
mode diver 1 0x00: No data; 0x01:
Last data;0x02: All data;
0x03 Specific data
Get Last Data / All Data / Specific Data
or don’t get data
0x01
block diver 2 0-6000 Specific block 0
Set Auto DXT Data response