Product Description

4.3.4 Commands/response description
4.3.4.1 Set Date/Time
Set RTC time.
OPCODE: 0x0001
field parameters is:
Day Month Year Hour Minutes
All the parameters are mandatory.
Field Size(bytes) Valid Range Description Default
Day 1 1-31 Day of the month N/A
Month 1 1-12 Month of the year N/A
Year 1 10-37 Year since 2000 N/A
Hour 1 0-23 Hour since midnight N/A
Minutes 1 0-59 Minutes after the hour N/A
When gateway is starting and RTC date is reset, default date is 1/1/2010 00:00. If a new date is set
and this is more recent than the old one, wakeup date for C2 configuration is automatically updated.
In C1 configuration, date is reset to default when gateway is turned off.
Set Date/Time Response
Field size Valid Range Description Default
Status 2 0x0001-0x0003 Result of the command N/A
4.3.4.2 Get Date/Time
Get RTC time.
OPCODE: 0x0002
field parameters is:
No parameter
Get Date/Time Response
Status