The ground around the antenna line on PCB has to be strictly
connected to the Ground Plane by placing vias every 2mm at
least;
Place EM noisy devices as far as possible from GE866-QUAD
antenna line;
Keep the antenna line far away from the GE866-QUAD power
supply lines;
If you have EM noisy devices around the PCB hosting the
GE866-QUAD, such as fast switching ICs, take care of the
shielding of the antenna line by burying it inside the
layers of PCB and surround it with Ground planes, or shield
it with a metal frame cover.
If you don't have EM noisy devices around the PCB of GE866-
QUAD, by using a micro strip on the superficial copper layer
for the antenna line, the line attenuation will be lower
than a buried one.