NOTE: The UART input line TXD (rx_uart) of the GE863-QUAD/PY is NOT internally pulled up with a
resistor, so there may be the need to place an external 47KΩ pull-up resistor, either the DTR
(dtr_uart) and RTS (rts_uart) input lines are not pulled up internally, so an external pull-up resistor
of 47KΩ may be required.
A power source of the internal interface voltage corresponding to the 2.8VCMOS high level is
available at the VAUX pad, whose absolute maximum output current is 50mA.
If VAUX is also used to supply a Camera no additional devices could be connected.
Pull-up resistors can be connected to the VAUX pad provided that the pulled-up lines are
GE863-QUAD/PY input lines connected to open collector outputs in order to avoid latch-up
problems on the GE863-QUAD/PY.
Care must be taken to avoid latch-up on the GE863-QUAD/PY and the use of this output line to
power electronic devices shall be considered with care, especially for devices that generate
spikes and noise such as level translators, digital ICs or microcontroller, failure in any of these
condition can severely compromise the GE863-QUAD/PY functionality.
NOTE: The input lines working at 2.8VCMOS can be pulled-up with 47KΩ resistors that can be
connected directly to the VAUX line.
NO disturbing devices should be powered with the VAUX line; otherwise the module functionality
may be compromised.