User's Manual

Telit GE863-GPS
Hardware User guide
1vv0300714, Rev. ISSUE#0, - 21/02/06
Reproduction forbidden without Telit Communication written authorization – All Right reserved – Right of modification reserved page 31 of 76
NOTE: The UART input line TXD (rx_uart) of the GE863-GPS is NOT internally pulled up with a
resistor, so there may be the need to place an external 47K pull-up resistor, either the DTR
(dtr_uart) and RTS (rts_uart) input lines are not pulled up internally, so an external pull-up resistor
of 47K may be required.
A power source of the internal interface voltage corresponding to the 2.8VCMOS high level is
available at the VAUX pad, whose absolute maximum output current is 50mA.
If VAUX is also used to supply a Camera no additional devices could be connected.
Pull-up resistors can be connected to the VAUX pad provided that the pulled-up lines are
GE863-GPS input lines connected to open collector outputs in order to avoid latch-up problems
on the GE863-GPS.
Care must be taken to avoid latch-up on the GE863-GPS and the use of this output line to power
electronic devices shall be considered with care, especially for devices that generate spikes and
noise such as level translators, digital ICs or microcontroller, failure in any of these condition
can severely compromise the GE863-GPS functionality.
NOTE: The input lines working at 2.8VCMOS can be pulled-up with 47K resistors that can be
connected directly to the VAUX line.
NO disturbing devices should be powered with the VAUX line; otherwise the module functionality
may be compromised.