TIP:
To check if the device has powered off, the hardware line PWRMON must be
monitored. When PWRMON goes low, then the device has powered off.
5.2.1. Hardware Unconditional Restart
WARNING:
The hardware unconditional Restart must not be used during normal operation of the
device since it does not detach the device from the network. It shall be kept as an
emergency exit procedure to be done in the rare case that the device gets stacked
waiting for some network or SIM responses.
To unconditionally Restart the GC864-QUAD / PY, the pad RESET# must be tied low
for at least 200 milliseconds and then released.
The maximum current that can be drained from the ON# pad is 0,15 mA.
A simple circuit to do it is:
NOTE:
Do not use any pull up resistor on the RESET* line nor any totem pole digital output.
Using pull up resistor may cause latch up problems on the GC864-QUAD / PY power
regulator and improper functioning of the module. The line RESET* must be
connected only in open collector configuration.
TIP:
The unconditional hardware reboot must always be implemented on the boards and
the software must use it as an emergency exit procedure.
Reproduction forbidden without Telit Communications S.p.A’s. written authorization - All Rights Reserved. Page 21 of 69