NOTE:
In order to be able to do in circuit reprogramming of the GC864-QUAD V2 / GC864-
DUAL V2 firmware, the serial port on the Telit GC864-QUAD V2 / GC864-DUAL V2
shall be available for translation into RS232 and either it is controlling device shall be
placed into tristate, disconnected or as a gateway for the serial data when module
reprogramming occurs.
Only RXD, TXD, GND, SERVICE and the On/off module turn on pad are required to the
reprogramming of the module, the other lines are unused.
All applicator shall include in their design such a way of reprogramming the GC864.