2 Hardware Commands
2.1 Turning ON the GC864
To turn on the GC864 the pad ON# must be tied low for at least 1 second and then released.
The maximum current that can be drained from the ON# pad is 0,1 mA.
A simple circuit to do it is:
NOTE: don't use any pull up resistor on the ON# line, it is internally pulled up. Using pull up
resistor may bring to latch up problems on the GC864 power regulator and improper power
on/off of the module. The line ON# must be connected only in open collector configuration.
NOTE: In this document all the lines that are inverted, hence have active low signals are
labeled with a name that ends with a "#" or with a bar over the name.
NOTE: The GC864 turns fully on also by supplying power to the Charge pad (provided there's
a battery on the VBATT pads).
ON#
Power ON impulse
GND
R1
R2
Q1