User's Manual
Field Valid Range Description Default
Status 2 0x0001-0x0003 Result of the command N/A
4.3.4.19 Get DXT Data
Send data from DXT over serial communication (C1 and C2) or FTP (only C2).
OPCODE:0x0013
Where field parameters is:
Address FTP/serial mode baro block baro mode diver block diver
All the parameters (except block parameters) are always mandatory. Block parameters are mandatory
if specific data is required.
Field Size Valid Range Description Default
Address 8 MAC address from
00-15-4F-00-00-00-00-00
to
00-15-4F-FF-FF-FF-FF-FF
or
00-00-00-00-00-00-00-00
DXT MAC address N/A
FTP/serial
1
0x00: serial, 0x01: FTP
Send
ing file mode
N/A
bode baro 1 0x00: No data; 0x01: Last
data;0x02: All data; 0x03
Specific data
Get Last Data / All Data / Specific
Data or don’t get data
N/A
block baro
2
0
-
6000
Specific block
N/A
mode diver 1 0x00: No data; 0x01: Last
data;0x02: All data; 0x03
Specific data
Get Last Data / All Data / Specific
Data or don’t get data
N/A
block diver 2 0-6000 Specific block N/A
If ZE60 module is off or in idle, it performs a wakeup session and then asks for data. If ZE60 module is
in comm session, scan is not performed.
FTP/serial can be only 0x00 for C1. If the Address is 00-15-4F-FF-FF-FF-FF-FF, data will be received
from all the connected DXTs. If the Address is 00-00-00-00-00-00-00-00, data will be received from all
the active DXTs from the saved list.
If you ask for baro and diver data, one comm slot is dedicated for baro and another one for diver.
Each comm slot will be executed only if there is enough time in the current comm session.
Status