User's Manual
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 43 of 73
Where field parameters is:
Address
MAC address parameter is mandatory.
Field Size Valid Range Description Default
Address 8 MAC address from
00-15-4F-00-00-00-00-00
to
00-15-4F-FF-FF-FF-FF-FE
DXT MAC address N/A
If the SR module in the gateway is off or in idle, it performs a wakeup session and then starts a comm
slot with the DXT. If the SR module in the gateway is in comm session, scan is not performed. Comm
slot will be ended after the registers are read and SR module in the gateway will be turn off.
Get DXT SR parameters response
Status Fast period Slow period
Field size Valid Range Description Default
Status 2 0x0001-0x0003 or
0x0006
Result of the command N/A
Fast period 1 1-254 Cyclic wakeup in sec during comm
session
N/A
Slow period 1 1-254 Cyclic wakeup in sec during wakeup
session
N/A
4.3.4.14 Scan for DXT
Look for active DXTs.
OPCODE:0x000E
Where field parameters is:
No parameters
Scan is performed if SR module is in off or idle state. After Scan, SR module goes to Comm Session.
Scan For DXT response
A
Scan Response,
one for each device, will be received