3.4.4 Switching the GG864-2.4 ON and OFF
3.4.4.1 Switching ON
The GG864-2.4 switches on automatically each time the power supply is connected the first time or re-
connected.
Note- When the power supply cable is disconnected, it is recommended to
wait approximately 5 seconds before applying the power again.
3.4.4.2 Switching OFF
The GG864-2.4 can be switched off either by disconnecting the power supply or by software
command.
It is suitable a software switch-off command before disconnect the power supply cable.
Warning Please note that hardware power off should be done only after
a proper GSM logoff. Any GSM device is request to issue a “detach”
request at turning off.
3.4.5 Antenna
3.4.5.1 Antenna Output
Warning BEFORE connecting the GG864-2.4 to a power supply source, suitable
antennas shall be connected and properly installed.
The antenna has to be installed with care to avoid any interference with other electronic devices
and has to guarantee a minimum distance from the body (20 cm). in case this requirement cannot
be satisfied, the system integrator has to assess the final product against the SAR regulation.
For a good efficiency of the antenna and a minimum interference with other electronic systems, a
space of min. 40 cm around the radiating part should be left free of electrically conducting materials.
The less distance and the fewer obstacles between the SWS-GW antenna and the antenna of the
GSM/GPRS network base station, the less power is radiated by the gateway and the better signal
quality is achieved.
3.4.5.2 Antenna Connectors
The GG864-2.4 includes two SMA bulkhead female, class 4 (2W) co-axial connectors for the two
external antennas.
3.4.5.3 GSM Antenna Requirements
The GSM antenna for GG864-2.4 device shall fulfill the following requirements
: