User's Manual

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 19 of 73
3.4 Interface Description
3.4.1 Power connector
The power connector on the left side of the terminal is a Molex 2-pins connector (part no.: 43045-
0210).
Pin description:
GND = Ground reference
Input Power = 5 - 15 VDC
Warning - Power Cable connecting the the power source to the Gateway shall
not exceed 3 meters lenght
3.4.2 Supply Voltage
The external power supply must be connected to power supply input as described in the following
subsection and must fulfil the following requirements:
Nominal Supply Voltage
12 volts
Min Supply Voltage
5 volts
Max supply Voltage
15 volts
Table 5 – Supply Voltage
Danger Operating voltage range must never be exceeded; care must be taken
in order to fulfill Min/Max voltage requirements.
3.4.3 Battery source
The external power supply could be sourced by an external no rechargeable battery.
Battery voltage range is 5 – 15V.
The battery capacity should be dimensioned on the customer’s application and battery life
requirements.