User Manual
GE863-PRO
3
Product Description
80285ST10036a Rev. 1 DRAFT- 24/04/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 34 of 53
4.11 Ethernet controller
The Application processor provides an Ethernet controller compatible with the 10Mb/s -100Mb/s IEEE
802.3 standard that can be used to interface the Telit GE863-PRO
3
to a LAN. It fully supports Media
Independent Interface (MII) or Reduced Media Independent Interface (RMII) standards to PHY
transceivers with MDIO controlling interface.
4.12 ADC with ADC trigger
The application processor provides an Analog Digital Converters with an ADC trigger input and a
4-to-1 analog multiplexer, making possible the conversion of up to 4 analog lines.
The characteristic of the ADC are:
Min Max Units
Voltage range
3.0 3.1 Volt
AD conversion
8 10 bits
ADC clock frequency
0 5 MHz
Max sampling rate
312 kS per second
4.13 DAC Converter
The Application processor is able to generate a PWM signal based on a specific percentage of duty
cycle decided by the user. An external filter is necessary to convert the PWM signal into a constant
voltage.
Min Max Units
Voltage range
3.0 3.1 Volt
Duty Cycle range
0 100 %
Resolution
1 1 %