Installation, Operation & Diagnostics for the MIU9.6FPD Industrial Grade, Digital Fast Poll Standalone Modem Document No. 49-0002-013 Rev.
Telenetics Corporation 26772 Vista Terrace Drive Lake Forest, California 92630 (949)455-4000 Fax (949)455-4010 Document No. 49-0002-013 Rev.
TABLE OF CONTENTS 1. STANDARDS.............................................................................................. 2 2. PRODUCT OVERVIEW ........................................................................... 3 3. GENERAL PRODUCT SPECIFICATIONS ............................................ 4 4. MODEM SPECIFICATIONS ................................................................... 5 5. ANALOG LINE SPECIFICATIONS ........................................................ 7 6.
1. STANDARDS Meets FCC Rules Part J, Subpart 15, Class A for radiated emissions. MIU9.
2. PRODUCT OVERVIEW The MIU9.6FPD is an industrial grade Digital Fast Poll modem designed for multidropping applications over unconditioned metallic lines (eg; pilot wires). Available as single channel device (MIU9.6FPD), 2-channel device (MIU9.6FPD/D) or repeater (MIU9.6FPD/R) The MIU9.6FPD can be powered from a wide range of AC and DC power supplies, it is internally surge protected on both the power and analog lines, and it will operate in temperatures from -40 to +85 deg C. Internally, the MIU9.
3. GENERAL PRODUCT SPECIFICATIONS Dimensions: Weight: 5.3 x 4.0 x 1.375 inches 1 lb Voltage Supply: Standard Model: 40 to 270VDC 40 to 270VAC, 50/60Hz 9 to 36VDC LV Model (Suffix “-LV”): Current Requirements: 12VDC 24VDC 125VDC 120VAC 220VAC MIU9.6FPD MIU9.6FPD/D MIU9.6FPD/R Surge Protection: Power Supply: Analog Line: Digital Line: 8kVrms 3.75kVac IEC255-5 ESD ± 10kV Operating Temperature: -40 to +85 deg C Operating Humidity: 0 to 90% (non-condensing.
4. MODEM SPECIFICATIONS Modulation: Pulse Position Modulation (PPM) Synch/Async: Asynchronous Only Data Rate: 0 – 1200bps Error Correction: Data Compression: None None Data Modulation Connectivity: Using 16ms Polling Test 99.999% or better at -37dBm 99.
Other Features Receiver Equalization: Compromise Equalization Self Test Diagnostics: None Local Analog Loopback: See Section 13 Local Digital Loopback: See Section 13 Remote Analog Loopback See Section 13 Remote Digital Loopback See Section 13 Anti-Streaming: OFF or 45 Seconds (+ 5 sec) * RTS/CTS delay: 1ms, 12ms, 35ms or 50ms (+5%) * Note: Soft Carrier will effect RTS/CTS delay time (see Dip Switch Settings ~ Section 8) Constant Carrier Switch Selectable ON or OFF Soft Carrier Turn Off 2
5. METALLIC CONDUCTOR SPECIFICATIONS The MIU9.6FPD contains digital circuitry for connection 2 or 4-wire metallic conductors (eg; pilot wires). The MIU9.6FPD will also interface to Power Line Carrier or Microwave radio voice channel networks. The MIU9.6FPD has an RJ-11terminated connector. The following lists the MIU9.6FPD conductor interfaces Conductor Type: Conditioned or unconditioned, Bell type 3002, 2 or 4-wire, full duplex voice grade or metallic lines or better.
6. POWER CONNECTIONS MIU9.
7. SERIAL DATA PORT PIN-OUTS MIU9.
8. DIP SWITCH FUNCTIONS IMPORTANT NOTE: Invert modem to view dip switches as shown above Table 1 Switch Switch 1 Switch 2 Switch 3 Switch 4 Switch 5 Switch 6 Function Antistreaming ON OFF Data Rate = 19200 bps Data Rate = 9600 bps Data Rate = 4800 bps Data Rate = 2400 bps MIU9.
9. LED INDICATOR MIU9.
10. OUTLINE DRAWING & MOUNTING MIU9.
11. DIAGNOSTICS The following pages provide hardware techniques for diagnosing communication problems and thereby isolating the problem at the local modem, the remote modem or the interconnecting line. (a) LOCAL ANALOG LOOPBACK (Figure 2) Requires a loop back cable with a built-in circuit for line loss to simulate a typical leased line condition (See Figure 3). Connect the loop back cable to the RJ11 connector on the modem under test.
Test 3: Received Signal Level Set Dip Switch 1 OFF (TxA = -10dBm) and Dip Switch 3 OFF (RxA = -43dBm). CD will be ON. Run a test message at TxD and verify that the same message is received at RxD with no data errors. Test 4: Repeat Test 3 for various RTS/CTS delay times and with soft carrier ON and OFF.
(c) REMOTE DIGITAL LOOPBACK – 4/Wire Network (Figure 5) Configure both the local and remote modems as follows: Switch 1 = ON (TxA = 0dBm) Switch 3 = ON (RxA = -33dBm) Switch 4 = OFF (RTS/CTS = 35ms) Switch 5 = ON (RTS/CTS = 35ms) Switch 6 = ON (Constant Carrier mode). Switch 7 = OFF (4-Wire) Switch 8 = ON (Line Termination = 600 ohms) Switch 9 = ON (Soft Carrier Turn Off = ON) Connect TxD to RxD at the remote modem.
(d) LINE DIAGNOSTICS (i) Typical modem configuration for 4-wire Point-to-Point system… Switch 1 = ON (TxA = 0dBm) Switch 3 = ON (RxA = -33dBm) Switch 4 = OFF (RTS/CTS = 1ms) Switch 5 = OFF (RTS/CTS = 1ms) Switch 6 = ON (Constant Carrier mode).
MIU9.
MIU9.
MIU9.
NOTES: MIU9.