Datasheet

2
1
3
4
5
6
7
8
9
10
5/31
Photo-electric sensors 1
OsiSense XU multimode
Design 18, metal or plastic
Three-wire DC, solid-state output
Characteristics
Sensor type XUB 0ppppM12, XUB 0ppppM12T XUB 0ppppL2, XUB 0ppppL2T
Product certications UL, CSA, e
Connection Connector M12
Pre-cabled Length: 2 m
Sensing
distance
nominal Sn /
(excess gain = 2)
maximum
(excess gain = 1)
Line of sight
along case axis
Line of sight 90° to
case axis
Accessory
m 0.12 / 0.12 0.11 / 0.11 Without (diffuse with background
suppression)
m 0.3 / 0.4 0.2 / 0.3 Without (diffuse)
m 2 / 3 1.5 / 2 With reector (polarised reex)
m 15 / 20 7 / 10 With thru-beam transmitter (thru-beam)
Type of transmission Infrared, except for polarised reex (red)
Degree of protection Conforming to IEC 60529 IP 65, IP 67, double insulation i
Storage temperature °C - 40…+ 70
Operating temperature °C - 25…+ 55
Materials Case: nickel plated brass for XUB 0B or PBT for XUB 0A; Lens: PMMA; Cable: PvR
Vibration resistance Conforming to IEC 60068-2-6 7 gn, amplitude ± 1.5 mm (f = 10 to 55 Hz)
Shock resistance Conforming to IEC 60068-2-27 30 gn, duration 11 ms
Indicator lights Output state Yellow LED (transmission present for XUB 0ppppppT)
Supply on Green LED
Optical alignment aid/dirty Red LED (except for XUB 0ppppppT)
Rated supply voltage V c 12…24 with protection against reverse polarity
Voltage limits (including ripple) V c 10…36
Current consumption, no-load mA 35 (20 for XUB 0ppppppT)
Switching capacity mA
100 with overload and short-circuit protection
Voltage drop, closed state V < 1.5
Maximum switching frequency Hz 250 (200 for diffuse with background suppression)
Delays First-up ms < 200
Response ms < 2 (< 2.5 for diffuse with background suppression)
Recovery ms < 2 (< 2.5 for diffuse with background suppression)
Wiring schemes
M12 connector Pre-cabled Receiver, PNP output Receiver, NPN output Thru-beam transmitter
3 (-)
1 (+)
4 OUT/Output
2 Beam break
input (1)
(-) BU (Blue)
(+) BN (Brown)
OUT/Output BK (Black)
Beam break input (1)
VI (Violet)
Input 2/VI:
- not connected: beam made
- connected to –: beam broken
See connection on page 9/44.
Detection curves (line of sight along case axis)
With thru-beam accessory (thru-beam) Without accessory
(diffuse)
Without accessory
(diffuse with background
suppression)
With reector
(polarised reex)
Object: 10 x 10 cm, 1: white 90%, 2 : grey 18% WithreectorXUZC50
Variation of usable sensing distance Su (without accessory, with adjustable background suppression)
Teach mode at minimum. Teach mode at maximum.
A-B:objectreection
coefcient
Black 6%
Grey 18%
White 90%
Sensing range
Non sensing zone
(matt surfaces)
Dimensions
XUB
Pre-cabled (mm) Connector (mm)
a b a b
Ø 18, line of sight along case axis 64 (2) 44 78 (2) 44
Ø 18, line of sight 90° to case axis 78 44 92 44
(1) Beam break input on thru-beam transmitter only.
(2) For XUB 0
ppppppT, 64 becomes 62 mm and 78 becomes 76 mm.
1 2
4 3
1 2
4 3
BN/1
BU/3
+
PNP
BK/4
BN/1
BU/3
+
PNP
BK/4
BN/1
BU/3
+
BK/4
NPN
BN/1
BU/3
+
BK/4
NPN
1/BN
3/BU
2/VI
1/BN
3/BU
2/VI
Sn y 15 m
15
-15
1510
20
m
Ø 12 mm
Sn y 15 m
15
-15
1510
20
m
Ø 12 mm
40
30 cm
40
30 cm
8
12 cm
12 cm
8
12 cm
12 cm
2
4
6
-2
-4
-6
2
m
3
2
2
4
6
-2
-4
-6
2
m
3
2
A
B
10
8
0,1
S (cm)
A
B
10
8
0,1
S (cm)
12
A
B
17
10
0,1
S (cm)
12
A
B
17
10
0,1
S (cm)
a
b
a
b
Characteristics,