User's Manual

4
1.2. Functionality
On/Off and dimming functionality using automatic DALI/ 0-10 volt selection
• Luminaire power consumption measurement to 1% accuracy
• Analog and digital input for interfacing with external sensors
• Auto-commissioning with GPS or NFC chip
• Internal or external configurations
• Highly secure wireless communication utilizing AES-128 or AES- 256
Enclosures - NEMA: ANSI C136.41, 7pin
• Dual backup protection – autonomous operation based on a pre-programmed scenario; built in light,
no dayburn
• Supports over the air firmware upgrade
• Data and settings preserved in case of power failure
• LCU NEMA stores history of measured parameters for at least a week to allow for data extraction
• Controlled Auxiliary Output (optional)
Includes the Telematics “Auto Detection and Verification” software that automatically detects and
stores the ballast type (1-10V or DALI) in the LCU NEMA. The ballast type is then retrieved during the
commissioning process, thereby eliminating the need to enter it manually into the CMS.
1.3. Reports
Reports of events related to exceeding established parameter limits
• Aggregate energy and active power consumption
• Burning hours
• Number of On/Off cycles
• Failure reports
• Various luminaire dynamic parameters such as: instantaneous levels of ambient light, power
consumption, voltage, current, power factor, temperature.
LCU NEMA