User's Manual
FP300RA User Manual
2140-72018-00-0A REV: A Page 19 Of 38
2.4.3.2 Cable Connections
Caution
The FP-300RA does not have an ON/OFF power switch, and will start
operating as soon as power is connected. Make sure that no power is
supplied until authorization to start operations is received.
1. Identify the cables to be connected to the FP-300RA in accordance with the site
installation plan.
2. Visually inspect the connectors for any signs of damage: do not attempt to
connect if shell or pins are bent. Thoroughly clean using a soft, clean brush to
remove dirt and foreign matter.
3. Route each cable to the prescribed connector and mate the connectors. For each
D-type connector, secure the connection by tightening the two screws; use a
wrench to tighten RF connectors. Do not exert excessive force.
4. Four cable tying points are provided around the FP-300RA: use cable ties to
secure the cables. To prevent stress caused by bending, make sure to leave
enough slack.
2.4.3.3 Final Inspection
1. Visually inspect the installation for proper execution, good workmanship and
compliance with the applicable practices and regulations.
2. Check cable connections, and check their routes. Make sure that cables are
securely routed and fastened.
3. Inspect the installation of the other system components in accordance with the
applicable instructions.
4. Correct any problems detected during the inspection.
5. After the inspection is successfully completed, refer to Chapter 3 to continue
with the preliminary configuration.
Warning
Do not apply power to the FP-300RA before explicit authorization is
received from the person in charge. The FP-300RA may start
transmitting as soon as power is applied, resulting in possible
exposure of personnel working near the antennas to microwave
radiation.
The FP-300RA must not be allowed to transmit without being
connected to an antenna, or to other matched (50Ω) load.